The CZF Magnetic Self-Priming Pump is a high-performance, leak-free pump designed for industrial, chemical, and municipal applications. Utilizing magnetic drive technology, the pump eliminates the need for conventional shaft seals, ensuring zero leakage and reduced maintenance requirements. Its self-priming capability allows it to handle low liquid levels, suction lifts, and challenging startup conditions, making it ideal for a wide range of fluid transfer operations.
The pump is constructed from high-quality stainless steel, fluorine-lined materials, or other corrosion-resistant alloys, depending on the chemical and temperature requirements. Its hermetically sealed magnetic drive prevents fluid leakage, providing a safe, environmentally friendly, and efficient pumping solution for hazardous, corrosive, or toxic liquids.
The CZF Magnetic Self-Priming Pump is widely applied in chemical processing, pharmaceutical manufacturing, food and beverage production, municipal water treatment, and industrial liquid handling systems. Optional features include variable frequency drive (VFD) compatibility, thermal protection, automatic priming systems, and PLC/SCADA integration, enhancing automation, precision, and reliability.

Magnetic Drive Technology
Eliminates conventional mechanical seals, preventing leakage.
Provides safe and environmentally friendly operation with hazardous or corrosive fluids.
Self-Priming Capability
Capable of priming itself without external devices, handling low liquid levels efficiently.
Suitable for applications requiring intermittent or variable suction conditions.
Robust and Corrosion-Resistant Construction
Pump casing and impeller made from stainless steel, fluorine-lined materials, or corrosion-resistant alloys.
Resistant to abrasion, corrosion, and chemical attack, extending service life.
Wide Flow and Pressure Range
Flow rates: 1–1000 m3/h, depending on model and configuration.
Head: up to 80 meters, suitable for medium to high-pressure applications.
VFD and Automation Ready
Compatible with variable frequency drives for precise flow control.
Supports PLC/SCADA integration for automated operations.
Leak-Free Operation
Hermetically sealed magnetic drive eliminates the risk of leakage.
Ideal for toxic, flammable, or aggressive fluids.
Thermal Protection
Integrated thermal sensors protect the pump motor from overheating.
Ensures safe continuous operation in high-temperature conditions.
Low Maintenance
Minimal moving parts and no mechanical seals reduce maintenance requirements.
Modular design allows easy inspection and replacement of components.
Versatile Applications
Chemical transfer, pharmaceutical liquids, food and beverage, municipal water, and industrial process fluids.
| Parameter | Specification Range |
Pump Type | Magnetic Self-Priming Pump |
Flow Rate | 1 – 1000 m3/h |
Head | Up to 80 meters |
Pressure | Up to 16 bar depending on configuration |
Operating Temperature | -20°C to +120°C (varies by material) |
Material of Construction | Stainless steel, fluorine-lined alloys, or other corrosion-resistant materials |
Impeller Type | Closed or open magnetic drive impeller |
Shaft Material | Stainless steel or corrosion-resistant alloy |
Seal Type | Hermetically sealed magnetic drive |
Motor Type | TEFC or submersible electric motor |
Cable Type | Chemical-resistant, insulated, submersible or dry type |
Drive Options | Electric motor, VFD compatible |
Installation Type | Horizontal self-priming |
Noise Level | <75 dB(A) depending on model |
Transfers corrosive chemicals, acids, alkalis, and hazardous liquids.
Suitable for chemical tanks, process circulation, and chemical injection systems.
Handles pharmaceutical liquids, sterile solutions, and sensitive compounds.
Ideal for clean-in-place (CIP) systems and hygienic fluid transfer.
Transfers viscous liquids, syrups, oils, and other food-grade materials.
Hermetic seal ensures contamination-free operation.
Efficiently pumps water, wastewater, and reclaimed liquids.
Reduces leakage risks in municipal and industrial water systems.
Used in cooling water, process liquids, and chemical circulation.
Provides reliable flow, stable pressure, and leak-free operation.
Safely transfers flammable, toxic, or environmentally sensitive liquids.
Hermetic magnetic seal prevents fluid escape and contamination.
Supports small-scale chemical, pharmaceutical, and food processing operations.
Easy to integrate with automation and monitoring systems.
Confirm pump installation, correct piping connections, and electrical setup.
Inspect magnetic coupling, impeller, and motor insulation.
Verify fluid compatibility with pump materials.
Ensure pump and suction line are primed with fluid if required.
Start motor at low voltage, gradually increase to operational voltage.
Monitor flow rate, pressure, vibration, and temperature.
Adjust VFD or control system to achieve desired flow and pressure.
Operate within rated flow, pressure, and temperature limits.
Regularly check magnetic drive, vibration, and pump performance.
Inspect impellers and casing periodically for wear or damage.
Reduce flow gradually before stopping motor.
Disconnect power and drain fluid from pump if necessary.
Inspect and clean pump for storage or maintenance.
Routine Inspection
Monitor vibration, noise, and magnetic coupling alignment.
Inspect impeller, casing, and bearing surfaces regularly.
Magnetic Coupling Maintenance
Check for wear, corrosion, or misalignment.
Replace worn or damaged components promptly.
Motor Maintenance
Check insulation resistance, bearing temperature, and cooling.
Lubricate bearings as required for motor type.
Seal Maintenance
Hermetically sealed magnetic drive requires minimal maintenance.
Inspect for wear or misalignment during scheduled checks.
Cable and Electrical Maintenance
Inspect power cables and connectors for damage.
Ensure proper grounding and insulation integrity.
Scheduled Overhaul
Recommended every 12–18 months depending on fluid and operation.
Inspect all internal components, replace damaged parts.
| Problem | Possible Cause | Solution |
Pump fails to prime | Air in suction line or low fluid | Check suction line, ensure proper fluid level |
Flow rate below specification | Impeller blockage or wear | Clean or replace impeller |
Excessive vibration or noise | Misalignment, bearing wear | Check alignment, replace bearings |
Magnetic coupling slippage | Overload or misalignment | Adjust alignment, reduce load |
Motor overheating | Overload, poor cooling | Check motor rating, ensure thermal protection works |
Leakage | Rare, check magnetic drive seal | Inspect magnetic coupling and alignment |
Corrosion or erosion | Fluid incompatibility | Verify material compatibility, clean pump |
Leak-Free Operation – Eliminates mechanical seals, ensuring zero leakage.
Self-Priming Capability – Handles low suction fluid levels and challenging startups.
Corrosion and Chemical Resistance – High-quality materials resist harsh fluids.
Energy-Efficient – Optimized impellers and hydraulic design reduce energy consumption.
Automation Ready – Compatible with VFD and PLC/SCADA integration.
Low Maintenance – Minimal moving parts reduce downtime and maintenance cost.
Wide Application Range – Suitable for chemical, pharmaceutical, food, municipal, and industrial fluids.
Certified Quality – ISO, CE, API certified for performance and reliability.
The CZF Magnetic Self-Priming Pump provides a safe, leak-free, efficient, and maintenance-friendly solution for industrial, chemical, pharmaceutical, municipal, and food-grade fluid handling. Its magnetic drive, self-priming capability, corrosion-resistant construction, and automation compatibility make it ideal for continuous, reliable, and environmentally safe fluid transfer operations.
Copyright ? Jiangsu Longjie Pump Manufacturing Co., Ltd.