The CF Magnetic Pump is a highly reliable, magnetically driven centrifugal pump designed for safe, leak-free fluid transfer in critical industrial applications. Unlike conventional centrifugal pumps with shaft seals, the CF Magnetic Pump utilizes a magnetic coupling to transmit torque from the motor to the impeller, ensuring completely sealed fluid paths. This eliminates leakage of hazardous, corrosive, or toxic liquids, making it ideal for chemical, pharmaceutical, food, and semiconductor industries.
The CF Magnetic Pump combines precision engineering, advanced materials, and high-efficiency design to deliver superior performance with minimal maintenance. It is particularly suitable for handling aggressive chemicals, solvents, acids, bases, high-purity liquids, and volatile fluids, where even minor leakage could pose safety risks, environmental hazards, or product contamination.
Its seal-less design reduces maintenance costs, prevents downtime, and enhances operational safety. Constructed with high-grade materials such as 316L stainless steel, Hastelloy, or PTFE-lined alloys, the CF Magnetic Pump ensures corrosion resistance, abrasion resistance, and long-term reliability in challenging industrial environments.

Seal-Less Design
Eliminates traditional mechanical seals, gaskets, and packing to prevent leaks.
Minimizes the risk of environmental contamination and equipment failure.
Magnetic Drive Technology
Uses high-strength neodymium magnets or ceramic magnets in a closed coupling.
Provides torque transmission without direct contact, reducing mechanical wear.
Corrosion and Chemical Resistance
Constructed from stainless steel 316L, Hastelloy C, or titanium.
Suitable for aggressive chemicals, acids, alkalis, and solvents.
High Efficiency and Low Noise
Optimized impeller design ensures high flow rates, low energy consumption, and minimal vibration.
Ideal for continuous operation in industrial production lines.
Compact and Space-Saving
Modular design allows flexible installation in tight spaces.
Lightweight construction simplifies integration with piping and automation systems.
Wide Range of Fluid Compatibility
Handles high-purity chemicals, flammable solvents, viscous liquids, and abrasive fluids safely.
Maintenance-Free Operation
No seals or packing reduce downtime and spare parts requirements.
Easy disassembly for inspection or replacement of the impeller and magnetic coupling.
Temperature and Pressure Capabilities
Operates safely within a temperature range of -40°C to +150°C, depending on material selection.
Handles pressures up to 10 bar (1 MPa) for standard models, higher for reinforced versions.
| Parameter | Specification Range |
Pump Type | Centrifugal, Magnetic Drive |
Flow Rate | 0.5 – 500 m3/h |
Head | 5 – 120 m |
Temperature Range | -40°C to +150°C (depends on materials) |
Pressure Rating | Up to 10 bar (standard), 16 bar (high-pressure variant) |
Materials of Construction | 316L SS, Hastelloy C, Titanium, PTFE-lined alloys |
Bearing Type | Anti-friction ceramic or PTFE bearings |
Seal Type | Seal-less, magnetic coupling drive |
Motor Options | IEC standard motors, variable frequency drives (VFD) |
Viscosity Range | Up to 1000 cP (depends on model and impeller selection) |
pH Range | 0 – 14 (for chemical resistant materials) |
Connection Type | Flanged (ANSI/DIN/JIS), Threaded, Sanitary (Tri-Clamp) |
Efficiency | Up to 85% hydraulic efficiency |
Noise Level | <65 dB(A) at full load |
Compliance | ISO 9001, CE, RoHS, FDA (for food-grade variants) |
The CF Magnetic Pump is extensively used in chemical plants for transferring corrosive acids, alkalis, solvents, and hazardous chemicals. Its seal-less design prevents leakage of toxic liquids, ensuring operator safety and environmental compliance. It is ideal for process tanks, reactors, and chemical dosing systems.
Used for high-purity fluid transfer, CF Magnetic Pumps meet stringent FDA and GMP standards. They are suitable for liquid formulation, sterile transfer, and chemical reactions, ensuring contamination-free operation.
Food-grade variants, made from 316L stainless steel with polished surfaces, are used for syrup, dairy, oil, or beverage transfer. The seal-less design prevents contamination, while the pump handles viscous liquids without clogging.
In semiconductor manufacturing, the pump transfers high-purity acids, etchants, and solvents in sensitive production processes. Magnetic coupling ensures no leakage of critical fluids that can damage wafers or equipment.
CF Magnetic Pumps handle sludges, chemical waste, and acidic effluents in water treatment plants. Seal-less operation ensures no leakage of hazardous substances, protecting operators and the environment.
Used for petrochemical transfer, fuel handling, and solvent circulation, the CF Magnetic Pump withstands aggressive hydrocarbon fluids without seal leakage.
Ideal for laboratory-scale chemical processes or pilot production lines requiring small-volume, leak-free pumping with precise flow control.
Used for fuel transfer, brine circulation, and chemical dosing, the CF Magnetic Pump resists corrosion in high-salinity environments.
Verify pump alignment with motor and piping system.
Ensure no foreign objects are present inside the pump.
Check that bearings are correctly lubricated or pre-lubricated as required.
Confirm electrical connections comply with motor voltage and frequency specifications.
Fill the pump casing with the fluid to prevent dry running.
Energize the motor, gradually increasing speed to operational RPM.
Observe for vibration, noise, or unusual heating at the coupling or bearings.
Check flow and pressure gauges to confirm correct operation.
Monitor temperature and pressure regularly.
Use variable frequency drives (VFDs) for precise flow control.
Ensure fluid viscosity and density are within the pump’s rated capacity.
Gradually reduce motor speed before stopping.
For viscous or solid-laden liquids, flush the pump with compatible solvent to prevent clogging.
Inspect bearings, impeller, and magnetic coupling periodically for wear.
Visual Inspection
Check the pump casing, impeller, and magnetic coupling for wear or corrosion.
Bearing Check
Replace bearings if abnormal noise or vibration occurs.
Coupling Maintenance
Inspect magnets for signs of cracking or detachment.
Ensure gap alignment between inner and outer magnets.
Cleaning
Flush pump with compatible solvents or water after transferring corrosive or viscous fluids.
Periodic Overhaul
Recommended every 6–12 months depending on application.
Replace bearings, check impeller clearances, and inspect housing for corrosion.
Lubrication
Most CF Magnetic Pumps are self-lubricated via pumped fluid, eliminating external oiling.
| Problem | Possible Cause | Solution |
Pump not delivering fluid | Air trapped or dry-running | Prime pump, ensure fluid is present |
Noise or vibration | Bearing wear or misalignment | Replace bearings, check alignment |
Reduced flow rate | Blocked impeller or high viscosity | Flush pump, reduce viscosity, check impeller |
Magnetic coupling slippage | Misalignment or gap too large | Adjust coupling distance, ensure proper alignment |
Leakage from pump connections | Loose flanges or damaged O-rings | Tighten flanges, replace seals |
Overheating of pump casing | Low flow or high ambient temperature | Increase flow, ensure cooling, check viscosity |
Leak-Free Operation – No mechanical seals eliminate fluid leakage risks.
Corrosion Resistance – High-quality materials handle aggressive chemicals safely.
Low Maintenance Costs – Seal-less design reduces downtime and spare parts.
Energy Efficient – Optimized hydraulic design minimizes power consumption.
High Reliability – Precision engineering ensures smooth, vibration-free operation.
Versatile Applications – Suitable for chemical, pharmaceutical, food, semiconductor, and marine industries.
Compact Design – Fits easily into restricted installations or retrofit projects.
Copyright ? Jiangsu Longjie Pump Manufacturing Co., Ltd.